2 objekt 6077h: torque actual value, 3 objekt 60c2h: interpolation time period, 6077h – BECKHOFF AX2000 CANopen communication profile User Manual
Page 87: 60c2h, Objekt 6077h: torque actual value, Objekt 60c2h: interpolation time period, Canopen drive profile

4.11.2
Objekt 6077h: Torque actual value
The torque actual value refers to the current torque in the motor. The scaling equates to 1/1000 of
the rated torque.
Index
6077
h
Brief description
Torque actual value
Object code
VAR
Number of elements
1
Access
ro
PDO mapping
possible
Value range
INTEGER16
Default value
0
4.11.3
Objekt 60C2h: Interpolation time period
The interpolation time period is used for the PLL (phase-locked loop) synchronized positioning
mode.
The time unit (Subindex 1) is determined on the basis of 10
interpolation time index
s; only multiples of
1 ms are permitted. The two values define the internal ASCII parameter PTBASE (multiples of
250 μs).
In order to make use of PLL synchronized mode, SYNCSRC must be set to 3 (synchronization over
CAN) or FPGA set to 3 (AX2xxx 600 only).
Index
60C2
h
Brief description
Interpolation time period
Object code
RECORD
Number of elements
3
Sub-Indexes:
Sub-index
01h
Brief description
Interpolation time units
Access
rw
PDO mapping
possible
Value range
UNSIGNED8
Default value
1
Sub-index
02h
Brief description
Interpolation time index
Access
rw
PDO mapping
possible
Value range
-123 ... 63
Default value
-3