Canopen drive profile – BECKHOFF AX2000 CANopen communication profile User Manual
Page 65

Sub-index
03
h
Brief description
velocity for homing
Unit
μm/s
Access
rw
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to define the velocity for homing movements.
Sub-index
04
h
Brief description
acceleration ramp for homing/jogging
Unit
ms
Access
rw
PDO mapping
not possible
Data type
UNSIGNED16
Value range
1 ... 32767
Default value
10
Used to set the acceleration ramp for homing and jogging. The ramp has a trapezoidal form. The
time that is set refers to the preset velocities homing and jogging movements.
Sub-index
05
h
Brief description
braking ramp for homing/jogging
Unit
ms
Access
rw
PDO mapping
not possible
Data type
UNSIGNED16
Value range
1 ... 32767
Default value
10
Used to set the acceleration ramp for homing and jogging. The ramp has a trapezoidal form. The
time that is set refers to the preset velocities homing and jogging movements. The emergency stop
ramp (ASCII parameter DECSTOP) is used as the braking ramp for homing movements to a hard-
ware limit-switch.
Sub-index
06
h
Brief description
reference offset
Unit
μm
Access
rw
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to set the reference offset, i.e. the actual position value displayed when homing has been
completed (Object 2070
h
, Sub-index 06
h
).
Sub-index
07
h
Brief description
velocity for jogging t
Unit
μm/s
Access
rw
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to define the jogging velocity.
CANopen for AX2000/2500
65
BECKHOFF
07/2007
CANopen Drive Profile