Sub-index
10
h
Brief description
operating time
Unit
min
Access
ro
PDO mapping
not possible
Data type
INTEGER32
Value range
-(2
31
-1) ... (2
31
-1)
Default value
0
Used to read out the operating time (hours) counter of the servo amplifier.
Sub-index
11
h
Brief description
enhanced status for TPDO 33
Unit
—
Access
ro
PDO mapping
possible
Data type
UNSIGNED32
Value range
0 ... (2
32
-1)
Default value
—
Description:
Bit
Value
Description
0
0x00000001
status input 1
1
0x00000002
status input 2
2
0x00000004
status input 3
3
0x00000008
status input 4
4
0x00000010
reserved
5
0x00000020
reserved
6
0x00000040
reserved
7
0x00000080
reserved
8
0x00000100
reserved
9
0x00000200
reserved
10
0x00000400
reserved
11
0x00000800
reserved
12
0x00001000
reserved
13
0x00002000
reserved
14
0x00004000
reserved
15
0x00008000
reserved
16
0x00010000
task active (position control)
17
0x00020000
homing/reference point set
18
0x00040000
home position
19
0x00080000
In-Position
20
0x00100000
position latched
21
0x00200000
free
22
0x00400000
signal position 1
23
0x00800000
signal position 2
24
0x01000000
signal position 3
25
0x02000000
signal position 4
26
0x04000000
initialization finished
27
0x08000000
free
28
0x10000000
motor standstill
29
0x20000000
safety relay
30
0x40000000
output stage enabled
31
0x80000000
error present
CANopen for AX2000/2500
83
BECKHOFF
07/2007
CANopen Drive Profile