1002h, Object 1002h: manufacturer status register (ds301), Beckhoff – BECKHOFF AX2000 CANopen communication profile User Manual
Page 30

4.2.1.3
Object 1002h: Manufacturer Status Register (DS301)
This Object contains the manufacturer-specific status register, which also contains AX2xxx war-
nings (see also ASCII Object DRVSTAT).
Index
1002
h
Name
Manufacturer Status Register
Object code
VAR
Data type
UNSIGNED8
Category
M
Access
ro
PDO mapping
not possible
Value range
UNSIGNED8
Default value
no
The following table shows the bit assignment for the status register:
Bit
Description
0
Warning 1: I²t-threshold exceeded
1
Warning 2: full regen power reached
2
Warning 3: lag/following error
3
Warning 4: response monitoring activated
4
Warning 5: power supply phase missing
5
Warning 6: software limit-switch 1 has been activated
6
Warning 7: software limit-switch 2 has been activated
7
Warning 8: faulty motion task started
8
Warning 9: no reference point set at start of motion task
9
Warning 10: PSTOP activated
10
Warning 11: NSTOP activated
11
Warning 12: motor default values were loaded
12
Warning 13: expansion board not functioning correctly
13
Warning 14: motor phase
14
Warning 15: erroneous VCT entry selected
15
Warning 16: reserve
16
motion task active
17
reference point set
18
actual position = home position
19
In Position
20
position latch made (positive edge)
21
reached Position 0
22
reached Position 1
23
reached Position 2
24
reached Position 3
25
reached Position 4
26
finished initialization
27
reached Position 5
28
speed = 0
29
safety relay has been activated
30
output stage enabled
31
error present
30
CANopen for AX2000/2500
CANopen Drive Profile
07/2007