5 object 6097h: acceleration_factor (ds402), 6097h, Object 6097h: acceleration_factor (ds402) – BECKHOFF AX2000 CANopen communication profile User Manual
Page 62: Beckhoff

4.5.2.5
Object 6097h: acceleration_factor (DS402)
The acceleration_factor converts the acceleration [unit: /s
2
] into the internal format of the
AX2000/2500.
At present, the numerator and divisor are read-only. The values are set to 1. If the acceleration_fac-
tor is 1, then the ramp settings (Object 6083
h
profile_acceleration and Object 6084
h
profile_deceler-
ation) will be provided as acceleration times [ms] required to reach the target speed (Object 6081
h
profile_velocity).
Index
0x6097
h
Name
acceleration_factor
Object code
ARRAY
Number of elements
2
Data type
UNSIGNED32
Sub-Indexes:
Sub-index
01
h
Brief description
numerator
Mode
pp, pv
Access
ro
PDO mapping
not possible
Unit
increments [incr]
Value range
0 ... (2
32
-1)
EEPROM
no
Default value
0
Sub-index
02
h
Brief description
divisor
Mode
pp, pv
Access
ro
PDO mapping
not possible
Unit
—
Value range
0 ... (2
32
-1)
EEPROM
no
Default value
0
62
CANopen for AX2000/2500
CANopen Drive Profile
07/2007
BECKHOFF