7 save parameters and restart, Save parameters and restart – BECKHOFF AX2500 User Manual

Page 83

background image

9.3.7

Save Parameters and Restart

You are going to finish setup and you have changed several basic parameters. Depend-
ing on the parameters you changed, two possible reactions can occur:

Configuration parameters changed

A warning appears, that you have to restart the amplifier. This is called "coldstart". Click
"YES". The parameters are saved to the amplifier's EEPROM automatically and a reset
command restarts the amplifier (takes a few seconds). For example, this happens after
motor or feedback selection.

Other parameters changed

No warning appears. Parameters are saved in the volatile RAM only.

Save the parameters to the EEPROM of the servo amplifier manually by clicking the sym-

bol

in the tool bar. A coldstart of the amplifier is not necessary.

Reset the amplifier

You can reset the amplifier manually (e.g. in case of an error). Click the iconl

.