beautypg.com

6 conductor cross-sections, 3 led display, Ambient conditions – BECKHOFF AX2500 User Manual

Page 20: Conductor cross-sections, Display, led, Enclosure protection, Mounting position, Noise emission, Pollution level, Site altitude

background image

6.2.5

Ambient conditions, ventilation, mounting position

Storage, transport

ð p.13

Supply voltage tolerances

main power

AX250x

AX251x

auxiliary supply

w/o brake and w/o fan
with brake or with fan

min 1x115V

-10%

AC / max 1x230V

+10%

, 50/60 Hz

min 3x115V

-10%

AC / max 3x230V

+10%

, 50/60 Hz

min 3x230V

-10%

AC / max 3x400V

+10%

, 50/60 Hz

20 VDC ... 30 VDC
24 VDC (-0% +15%), check voltage drop

Ambient temperature in operation

0...+45

o

C at rated conditions

+45...+55°C with power derating 2.5% / K

Humidity in operation

rel. humidity 85%, no condensation

Site altitude

up to 1000m amsl without restrictions
1000...2500m amsl with derating 1.5% / 100m

Pollution level

Pollution level 2 as per EN 60204 / EN 50178

Vibrations

Class 3111 according to IEC 721-3-3

Noise emission

max. 45 dB(A)

Enclosure protection

IP 20

Mounting position

normally vertical

ð p.34

Ventilation

AX25x3: free convection
AX25x6: add-on fan (

ð p.36)

Make sure that there is adequate forced ventilation in the closed control cabinet.

6.2.6

Conductor cross-sections

Technical requirements to cables

ð p.41.

Following EN 60204-1, we recommend :

AC connection

1.5 mm², depending on the system fusing

Motor cables, max. 25m

1 mm², shielded, capacitance <150pF/m

Resolver, motor thermostat,
max.100m

4x2x0.25 mm², twisted pairs, shielded,
capacitance <120pF/m

Encoder, motor thermostat,
max. 50m

7x2x0.25 mm², twisted pairs, shielded,
capacitance <120pF/m

Analog signals

0.25 mm² , twisted pairs, shielded

Control signals, BTB, DGND

0.5 mm²

Holding brake (motor)

0.75 mm², shielded, check voltage drop

+24 V / XGND

max. 2.5 mm²
Check voltage drop and total current!

To reach the max. permitted cable length, observe cable requirements

ð p. 41.

6.3

LED display

A 3-digit LED display indicates the amplifier status after switching on the 24V supply
(

ð p.89).

20

AX2500 Product Manual

Technical description

06/2007

BECKHOFF