3 digital outputs (x3), Digi-out 1/2, Digital outputs (x3) – BECKHOFF AX2500 User Manual
Page 65: P.65

8.16.3
Digital outputs (X3)
Technical characteristics
—
Ground reference is Digital-GND (DGND, terminal X1/4,5 on the master)
—
Alle digital outputs are floating
—
DIGITAL-OUT1 and 2 : Open-collector, max. 30 V DC, 10 mA
—
Update rate: 250 µs
Programmable digital outputs DIGITAL-OUT 1 / 2:
You can use the digital outputs DIGITAL-OUT1 (terminal X3/8) and DIGITAL-OUT2
(terminal X3/9) to output messages from pre-programmed functions that are stored in the
servo amplifier.
A list of the pre-programmed functions can be found in the Online Help.
If an input is freshly assigned to a pre-programmed function, then the data set must be
stored in the EEPROM of the servo amplifier, and the 24 V auxiliary supply of the servo
amplifier must be switched off and on again (to reset the amplifier software).
AX2500 Product Manual
65
BECKHOFF
06/2007
Electrical Installation
AX2500
- Bus Terminal System (19 pages)
- EP-xxxx-xxxx (19 pages)
- BK2000 (30 pages)
- LC3100 (67 pages)
- BK4000 (28 pages)
- BK3xx0 (95 pages)
- BK5000 (12 pages)
- LC5200 (32 pages)
- BK7000 (29 pages)
- BK7500 (32 pages)
- BK7300 (40 pages)
- BK8100 (26 pages)
- BC2000 (28 pages)
- BC3100 (51 pages)
- BC7300 (48 pages)
- BC8100 (36 pages)
- BC3150 (112 pages)
- KL1012 (2 pages)
- KL1114 (2 pages)
- KL1164 (1 page)
- KL1232-xxxx (4 pages)
- KL1501 (19 pages)
- KL1512 (15 pages)
- KL2521-0024 (18 pages)
- KL2512 (21 pages)
- KL2612 (4 pages)
- KL2622 (9 pages)
- KL3062 (24 pages)
- KL3064 (20 pages)
- KL4132 (19 pages)
- KL4034 (25 pages)
- KL3302 (23 pages)
- KL3351 (18 pages)
- KS3681 (43 pages)
- KL4112 (18 pages)
- KL5001 (16 pages)
- KL5051 (17 pages)
- KL5101-0012 (21 pages)
- KS5111-0000 (21 pages)
- KL5121 (19 pages)
- KL6021 (20 pages)
- KL6051 (17 pages)
- Z1000 (2 pages)
- KL6071 (12 pages)
- Z1003 (2 pages)