3 hardware requirements, 4 operating systems, Hardware requirements – BECKHOFF AX2500 User Manual
Page 75: Software, Operating systems

9.2.1.3
Hardware requirements
The PC interface (X6, RS232) of the master is connected to a serial interface on the PC
by a null-modem cable (not a null-modem link cable !) (
ð p.67).
Connect / disconnect the interface cable only when the supply is switched off for
both the PC and the servo amplifier.
The interface in the servo amplifier is electrically isolated by an optocoupler, and is at the
same potential as the CANopen interface.
Minimum requirements for the PC:
Processor
:
Pentium I or higher
Operating system :
WINDOWS 98 / 2000 / ME / NT4.0 / XP
Graphica adapter :
Windows compatible, color
Drives
:
Hard disk (10 MB free space)
CD-ROM drive
Main memory
:
at least 8 MB
Interface
:
one free serial interface (COM1... 10)
9.2.1.4
Operating systems
WINDOWS 98 / 2000 / ME / NT / XP
DRIVE.EXE can work under WINDOWS 98 / 2000 / ME / XP or WINDOWS NT 4.0.
Emergency operation is possible with an ASCII terminal-emulation.
Interface setting: 9600 bps, databit 8, stopbit 1,no parity, no handshake
Unix, Linux
DRIVE.EXE does not work under Unix and Linux.
9.2.2
Installation under WINDOWS 98 / 2000 / ME / NT / XP
The CD-ROM includes an installation program for the setup software.
Installation
Insert the CD-ROM into a free drive.
Autostart activated:
The start screen of the CD-ROM pops up. Click on the link to the Setup Software and
follow the instructions.
Autostart deactivated:
Click on START (task bar), then on Run. Enter the program call x:\index.htm (where x is
the drive letter for the CD drive). Click on OK and then on the link to the Setup Software
and follow the instructions.
Connection to the serial interface of the PC
Connect the interface cable to a serial interface on your PC and the PC interfaces (X8) of
the AX2500 (
ð p.67).
AX2500 Product Manual
75
BECKHOFF
06/2007
Setup