beautypg.com

16 digital and analog inputs and outputs, 1 analog input (x3), Control signals – BECKHOFF AX2500 User Manual

Page 63: Analog in, Setpoint input, Analog input (x3), 63ff, P.63

background image

8.16

Digital and analog inputs and outputs

8.16.1

Analog input (X3)

The servo amplifier has a programmable input for analog setpoints.
AGND (X3/1) must always be joined to the CNC-GND of the controls to provide a ground
reference.

Technical data

Input voltage max. ± 10 V

Resolution 1.25 mV

Ground reference AGND, terminal X3/1

Input resistance 20 k

W

Common mode voltage range for both inputs ± 10 V supplementary

Update rate: 62.5 µs

Input Analog-IN (terminals X3/2-3)
Input voltage max. ± 10 V, 14-bit resolution, scalable
Standard setting: Speed Setpoint

Fixing the direction of rotation
Standard setting:

clockwise rotation of the motor shaft (looking at shaft end)
with positive voltage on terminal X3/3 (+ ) against X3/2 ( - )

To reverse the direction of rotation you can swap the connections to terminals X3/2-3 or
change the DIRECTION parameter in the SPEED screen.

AX2500 Product Manual

63

BECKHOFF

06/2007

Electrical Installation

AX2500