9.3.5
Motor (synchronous)
Press function key F12 (disable) before changing motor parameters.
Motor Type: Select Synchronous Motor. If you use a linear motor or an induction motor,
please contact our support department.
Number-Name: Click the list to start uploading the motor parameter table, which is stored
in the servo amplifier. Search and select the connected motor. If your motor is not listed,
please contact our support department.
Leave all other fields unchanged.
Click OK.
If your motor has a built-in brake, click
"Yes", otherwise "No".
If Software Enable is active, a warning
appears. You can proceed, but after the
amplifier is restarted, you must check
whether the holding brake configuration is
correct.
Click OK.
Parameters are uploaded to the ampli-
fier's RAM now (takes some seconds).
When this is done, you have to accept the
changed configuration with "Yes" or to
discard the changes in the appearing
screen.
If you click "Yes", the parameters are sa-
ved in the EEPROM and the amplifier
makes a coldstart (reset). This takes
some seconds.
On the start screen, click "Feedback" button.