Page 39: Wiring, Important notes

background image

8.3

Wiring

8.3.1

Important notes

Only professional staff who are qualified in electrical engineering are allowed to
install the servo amplifier.

The installation procedure is described as an example. A different procedure may be
appropriate or necessary, depending on the application of the equipment.

We provide further know-how through training courses (on request).

Caution !
Only install and wire up the equipment when it is not live, i.e. when neither the
mains power supply nor the 24 V auxiliary voltage nor the operating voltages of
any other connected equipment is switched on.
Take care that the cabinet is safely disconnected (lock-out, warning signs etc.).
The individual voltages will be switched on for the first time during commissioning.

The ground symbol

X

, which you will find in all the wiring diagrams, indicates

that you must take care to provide an electrically conductive connection with the
largest possible area between the unit indicated and the mounting plate in the
control cabinet. This connection is for the effective grounding of HF interference,
and must not be confused with the PE symbol

W (protective earth to EN 60204).

Use the following wiring and connection diagrams :
Overview:

Master module

: Page 45

Axis module

: Page 46

Mains power

: Page 47

Motor

: Page 48

Feedback

: Page 49ff

Electronic Gearing / Master Slave

Master/slave

: Page 56

Pulse/direction

: Page 59

Encoder emulation:

ROD (A quad B)

: Page 61

SSI

: Page 62

Digital&Analog I/Os

: Page 63ff

RS232 / PC

: Page 67

Fieldbus:

CAN interface

: Page 68

PROFIBUS interface

: Page 69

SERCOS interface

: Page 70

EtherCAT interface

: Page 71

Multiaxis systems

: Page 87

AX2500 Product Manual

39

BECKHOFF

06/2007

Electrical Installation