BECKHOFF AX5805 Installation User Manual
Page 83

Product description
AX5805
81
Index
Name
Description
Sub-
inde
x
Unit
Default
value
0x6694 t_L SLS
:006
Minimum time until the activation of the
SLS_6 safety function, if the speed is within
the window
06
1 ms
0x0000
0x6694 t_L SLS
:007
Minimum time until the activation of the
SLS_7 safety function, if the speed is within
the window
07
1 ms
0x0000
0x6694 t_L SLS
:008
Minimum time until the activation of the
SLS_8 safety function, if the speed is within
the window
08
1 ms
0x0000
0x6698 Error
Reaction
SLS :001
Error reaction of SLS_1
01
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :002
Error reaction of SLS_2
02
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :003
Error reaction of SLS_3
03
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :004
Error reaction of SLS_4
04
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :005
Error reaction of SLS_5
05
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :006
Error reaction of SLS_6
06
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :007
Error reaction of SLS_7
07
--
0x66400001
(STO)
0x6698 Error
Reaction
SLS :008
Error reaction of SLS_8
08
--
0x66400001
(STO)