3 technical data – BECKHOFF AX5805 Installation User Manual
Page 14

Product description
12
AX5805
3.3 Technical data
Product name
AX5805
Fault response time
see tables in chapters 3.3.1 and 3.3.2
Safety input process image
(dependent on the AX5000)
7 bytes (AX51XX) or 11 bytes (AX52XX)
Safety output process image
(dependent on the AX5000)
7 bytes (AX51XX) or 11 bytes (AX52XX)
Standard input process image
(dependent on the AX5000)
8 bytes (AX51XX) or 16 bytes (AX52XX)
Standard output process image
(dependent on the AX5000)
8 bytes (AX51XX) or 16 bytes (AX52XX)
Supply voltage of the AX5805
Supplied by the AX5000 servo drive
Dimensions (W x H x D) including cover plate
26 mm x 100 mm x 54 mm
Weight
approx. 75 g
Permissible ambient temperature (operation)
0°C to +50°C
Permissible ambient temperature
(transport/storage)
-25°C to +70°C
Permissible air humidity
5% to 95%, non-condensing
Permissible air pressure
(operation/storage/transport)
750 hPa to 1100 hPa
Permissible contamination level
Contamination level 2 according to EN 61800-5-1
(see also chapter ‘Cleaning’)
Unacceptable operating conditions
TwinSAFE products must not be used under the
following operating conditions:
-
in the presence of ionizing radiation
-
in corrosive environments
-
in an environment that leads to contamination
of the safety option card
EMC immunity / emission
conforms to EN 61800-5-1 / EN 61326-3-1
Protection class
IP20
Permitted operating environment
control cabinet or terminal box with minimum protection
class IP54 according to IEC 60529
Permissible installation position
vertical
Approvals
CE, TÜV Süd
The user must ensure that the TwinSAFE option card is only transported, stored and operated under the
conditions specified in technical data (refer to table above).
WARNING
Prohibited operating conditions
The TwinSAFE drive option cards may not be used under the following operating
conditions:
-
in the presence of ionizing radiation
-
in corrosive environments
-
in an environment that leads to contamination of the safety option card