3 diagnose coe object 0xfa10 – BECKHOFF AX5805 Installation User Manual
Page 102

Error and diagnosis
100
AX5805
4.3 Diagnose CoE Object 0xFA10
The CoE Object 0xFA10 supplies the user with additional diagnostic information. When sub-index 01 is set to
one of the values in the headings below, sub-indices 02 to 08 show the information in the corresponding
table.
The error and diagnostic values correspond to the information described in Chapter 4.2 .
4.3.1 0xFA10:01 = 0
Index in
0xFA10
Name
Description
0xFA10:02
-
-
0xFA10:03
Internal Data
-
0xFA10:04
Internal Data
-
0xFA10:05
Software CRC C1
-
0xFA10:06
Software CRC C2
-
0xFA10:07
Reason for shut-down Axis 1
Refer to Chapter 4.2
0xFA10:08
Reason for shut-down Axis 2
Refer to Chapter 4.2
4.3.2 0xFA10:01 = 1
Index in
0xFA10
Name
Description
0xFA10:02
Error 1 in C1
Refer to Chapter 4.2
0xFA10:03
Error 2 in C1
0xFA10:04
Error 3 in C1
0xFA10:05
Error 4 in C1
0xFA10:06
Error 5 in C1
0xFA10:07
Error 6 in C1
0xFA10:08
Error 7 in C1
4.3.3 0xFA10:01 = 2
Index in
0xFA10
Name
Description
0xFA10:02
Error 8 in C1
Refer to Chapter 4.2
0xFA10:03
Error 9 in C1
0xFA10:04
Error 10 in C1
0xFA10:05
Error 11 in C1
0xFA10:06
Error 12 in C1
0xFA10:07
Error 13 in C1
0xFA10:08
Error 14 in C1