BECKHOFF AX5805 Installation User Manual
Page 66

Product description
64
AX5805
3.6.5.9
Description of the SSM safety function
Figure 32: Description of the Safe Speed Monitor function (SSM0, SSM1)
The SSM function only performs monitoring; it indicates when the speed of the axis is within the range
specified by the SSM parameters. The SSM monitoring is activated by entering values in the SSM
parameters (n_UL_SSM_x or n_LL_SSM_x in Figure 32 unequal to 0). The status is set if the current speed
is within the limits n_UL_SSM 32 Bit (UL-Upper limit) and n_LL_SSM 32 Bit (LL-Lower limit).
SSM
1
t
SSM_1
1
SSM_2
1
t
t
t
n_LL_SSM_1
Speed
activated by parameter
n_UL_SSM_1
n_UL_SSM_2
n_LL_SSM_2
This manual is related to the following products: