Horn Replacement / Adjustment

HORN STACK

FRONT COVER

KNIFE GUARD

HORN MOUNT SCREW

HORN MOUNT

EXIT CONVEYOR

GEAR GUARD

FIGURE 10

For horn replacement or adjustment remove the Sonic Knife cover, Knife Guard and
the exit conveyor. Remove the horn mount screws and horn clamp screws. Remove
the horn mount and horn clamp. The horn will slide out from its mount.

When replacing the horn, before tightening the horn clamp screws, make sure the
horn is parallel with the knife blade. Replace and tighten the horn mount screws.
Replace and tighten the horn clamp screws and follow the procedure for leveling the
knife blade.