Ultra sonic power supply, Caution, Line cord – Avery Dennison SNAP Sonic Knife User Manual
Page 10: Fuse, Rf cable to sonic converter
Users Manual Sonic Knife w/500
Operation •••• 10
Ultra Sonic Power Supply
Caution
Only qualified technicians should service the power supply.
The ultrasonic attachment is made up of several components. They are the power
supply, the horn assembly and the connecting cable. In addition there is a knife
assembly with a changeable tool steel blade.
The power supply should be located next to the Sonic Knife. This unit generates
electrical pulses at 35 KHz to the converter. The power supply must be turned on
and off separately from the main printer. The power supply contains no ON/OFF
switch. Power on/off is accomplished by either plugging/unplugging the power
supply. The front display has several setting adjustments and status indicators.
Line Cord
Connects the power supply to line power.
Fuse
Refer to the nameplate on the ultrasonic power supply for replacement fuse
information.
RF Cable to Sonic Converter
Interface cable from the power supply to the converter.