Avery Dennison Monarch 9855 Operator Handbook User Manual
Page 36

4-2 Operator's Handbook
The options are listed in the table below.
Option
Choices
Default
Supply T ype
Aperture/Die Cut/Black
Mark/Continuous
Die Cut
Ribbon
No/Yes/High Energ y
Yes
Speed
2.5/4.0/6.0/8.0/10.0/12.0/Default
Default
Feed Mode
Continuous/On-Dem and
Continuous
Backfeed
Off/On/Extended
Off
Print Position
-450 to 450
0
Supply Position
-300 to 300
0
Margin Position
-99 to 99
0
Cut Position
-300 to 300
0
Dispense
Position
50 to 200
65
Backfeed
Distance
10 to 200
65
Separators
No/Yes/Long
No
Skip Index
No/Yes
No
Knife Control
-20 to 20
0
Error Action
Norm al
Overstrike/Continue x1
Overstrike/Continue x2
Overstrike/Continue x3
Overstrike/Continue x4
Overstrike/Continue x5
Norm al
Contrast
-699 to 699
0
To exit an option without changing the setting, press Escape/Clear.