AMETEK CSW Series User Manual
Page 41

User Manual
California Instruments
CSW Series
41
7. Program the power source to the Constant Current mode by first pressing the MENU key
several times to select UTILITY 1. Then select VOLT/CURR CONTROL and then OL
MODE. Program CC. Using the PROGRAM screen set the output current limit value to 8
amps. The system should go into current limit at the program value. Return the current
value to 16.0 amps and press the output on/off button to turn the output off. Disconnect the
load.
8. Repeat steps 4 through 7 but set the output for the following: output voltage = 312 volts,
output range = 230 volts, current limit = 8.0 amps. For step 7, the current limit value can be
set to 4 amps.
9. Repeat steps 4 through 8 for each of the three phases.
In the unlikely event the power source does not pass the functional test, refer to the calibration
procedure in Section 6 or call the Ametek customer service department for further assistance.
- CW-M (48 pages)
- CW-M Corrected Table 4-2 in (1 page)
- CW-P (62 pages)
- Lx Series (205 pages)
- CW Series Programming Manual (25 pages)
- Ls Series II Programming Manual (242 pages)
- Compact i/iX Series (157 pages)
- Compact IX 2253 (157 pages)
- Compact i/iX Series Software Manual (203 pages)
- ASD Series Quick Start (5 pages)
- ASD Series (120 pages)
- i-iX Series II Programming Manual (226 pages)
- DLM 600W Series Programming Manual (24 pages)
- M131 Programming Manual (99 pages)
- DLM Series (74 pages)
- DLM 600W Series (82 pages)
- BPS Series (153 pages)
- DLM600 Series (16 pages)
- DCS-E 1.2kW Series (65 pages)
- DLM-E 4kW Series Programming Manual (32 pages)
- M136 (8 pages)
- DCS-E 3kW Series (94 pages)
- CTS 3.0 (166 pages)
- 2003RP (126 pages)
- 2001RP (131 pages)
- MX CTSH (151 pages)
- MXCTSL Administrator Manual (27 pages)
- MX CTSL (157 pages)
- RS Series (228 pages)
- MX Series Installation Manual (35 pages)
- Ls AC source (2 pages)
- MX15 Series (184 pages)
- Ls Series II (226 pages)
- Lx Series Driver Manual (275 pages)
- MX Series Rev: AY (257 pages)
- iX Series (341 pages)
- i-iX Series II (258 pages)
- GUPS 2400A-108 (36 pages)
- HPD Series (58 pages)
- HPD Series Operation Manual (41 pages)
- HPD Series GPIB-Multichannel (134 pages)
- PLA-PLW Programming Manual (74 pages)
- ReFlex Mating Connnectors for Controller (3 pages)
- LPDC-16V (4 pages)