beautypg.com

AMETEK CSW Series User Manual

Page 164

background image

User Manual

California Instruments

164

CSW Series

8.4 WHM Option

8.4.1 General

This section describes the WHM option for the CSW Series Power Source.

8.4.2 Specification

All specifications are the same as the standard CSW Power Source specifications in addition to
the following specifications:

Watt-hour

0-6.000KW

0.01KWH + 0.1% <100Hz

0.02KWH +0.1% 100-500Hz

>6.000KW

Times three of the above specification

8.4.3 Local Operation

From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 8-32. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.

Figure 8-32: Application Screen

The WATT-HOURS METER screen shown in Figure 8-33 has the following fields:

Figure 8-33 Watt-Hour Meter Screen

START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when
the field is highlighted will activate the watt hour function and the field will change to STOP as
shown in Figure 8-34.

1. ETIME: This field will accumulate the time in hours, minutes and seconds.

2. WATT HR: This field will accumulate the watt-hour in KWH.

3. POWER: This field will report the instantaneous power in KW.

4. PK CURR: This field will report the peak current and will hold the maximum reading.

Figure 8-34: WH-Meter Screen With Function Active