CSW Series
System Specification (continued)
Parameter
Specification
Front Panel Trigger,
BNC connector
Output available at the front panel BNC connector that provides a
negative going pulse for any programmed voltage or frequency
change. The trigger can be reassigned as an output when running list
transients.
Front Panel Phase
A, B and C, BNC
connectors
These three outputs are representative of the programmed output
waveform, magnitude and frequency. 0 to 4.86 Vrms represents 0 to a
full-scale output voltage. The output impedance is 100 ohms.
External Signal
Individual inputs for an external signal for each of the three phases. A 0
to 5.0 Vrms input provides a 0 to full-scale output voltage of the supplied
waveform. Not available with FC option
External Gain
Control (RPV)
Individual inputs for an external DC signal for each of the three phases. A
0 to ±7.07 VDC signal provides a 0 to full-scale output voltage.
/INHIBIT
A logic Lo or contact closure input to inhibit the outputs
MOD
An input for an amplitude modulation. 0 to 5 Vrms provides 0 to
≥
20%
modulation for each of the three output phases
Trigger Input
An input to trigger a function
External Synch
A TTL input to frequency synchronize the outputs. The Phase A output
can be programmed relative to the external input. Not available with FC
option.
2.1.6 Unit Protection
Parameter
Specification
Input Overcurrent:
Circuit breaker with current trip control.
Input Overvoltage:
Automatic trip of input circuit breaker.
Input Overvoltage
Transients:
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Output Overcurrent:
Adjustable level constant current mode with a maximum set point
between 0% and 10% above programmed value.
Output Short Circuit:
Peak and rms current limit.
Overtemperature:
Automatic shutdown.