AMETEK CSW Series User Manual
Page 25
User Manual
California Instruments
CSW Series
25
2.1.5 System Specification
Parameter
Specification
NV memory storage: 16 complete instrument setups and transient lists, 100 events per list.
Waveforms
Sine, square, clipped, user defined
Transients
Voltage: drop, step, sag, surge, sweep
Frequency: step, sag, surge, sweep
Voltage and Frequency: step, sweep
IEEE-488 Interface:
SH1, AH1, T6, L3, SR1, RL2, DC1, DT1
IEEE 488.2 and SCPI
Response time is 10 ms (typical)
RS232C Interface:
Bi-directional serial interface
9 pin D-shell connector
Handshake: CTS, RTS
Data bits: 7, 8
Stop bits: 1,2
Baud rate: 9600, 19200, 38400 (Models without USB I/F)
Baud rate: 9600, 19200, 38400, 57600, 115200, 230400, 460800
IEEE 488.2 and SCPI.
Note: Disconnect any USB connection when using the RS232 interface.
USB Interface:
Standard USB 1.1 peripheral.
Data transfer rate: 460,800 bps
Syntax: IEEE 488.2 and SCPI.
Note:
Use of the USB port to control more than one power source
from a single PC is not recommended, as communication may not be
reliable. Use GPIB interface for multiple power source control.
LAN Interface:
Option –LAN. When the LAN interface is installed, the RS232 interface is
disabled.
RJ45 Connector, 10BaseT, 100BaseT or 1000BaseT,
Data transfer rate: 460,800 bps
Protocol: TCP/IP.
Syntax: IEEE 488.2 and SCP
Note: Disconnect any USB connection when using the LAN interface.
Current Limit
Modes:
Two selectable modes of operation.
Constant current and constant voltage with hold-off time and trip.