beautypg.com

Jumpers – Zilog EZ80L92 User Manual

Page 38

background image

eZ80L92 Development Kit
User Manual

Operational Description

UM012913-0407

34

PB2
The PB2 push button switch, SW3, is connected to bit 2 of the general-
purpose port. This switch can be used as the port input.

RESET
The Reset push button switch, SW4, resets the eZ80

®

CPU and the

eZ80Acclaim!

®

Development Platform.

Jumpers

The eZ80Acclaim!

®

Development Platform provides a number of jump-

ers that are used to enable or disable functionality on the platform, enable
or disable optional features, or provide protection from inadvertent use.

Jumper J2
The J2 jumper connection enables/disables IrDA transceiver functional-
ity. When the shunt is placed, IrDA communication is disabled. See

Table 13

.

Table 13. J2—DIS_IrDA

Shunt
Status

Function

Affected Device

IN

IrDA interface disabled UART0 is configured to work with the RS232 or the

RS485 interfaces.

OUT

IrDA interface enabled The IrDA and UART0 interfaces on the eZ80L92

Module perform their functions.