beautypg.com

Zilog EZ80L92 User Manual

Page 16

background image

eZ80L92 Development Kit
User Manual

Operational Description

UM012913-0407

12

Table 2. eZ80Acclaim!

®

Development Platform Peripheral Bus Connector

Identification—JP1

1

Pin No.

Symbol

Signal Direction

Active Level

eZ80L92 Signal

2

1

A6

Bidirectional

Yes

2

A0

Bidirectional

Yes

3

A10

Bidirectional

Yes

4

A3

Bidirectional

Yes

5

GND

6

V

DD

7

A8

Bidirectional

Yes

8

A7

Bidirectional

Yes

9

A13

Bidirectional

Yes

10

A9

Bidirectional

Yes

11

A15

Bidirectional

Yes

12

A14

Bidirectional

Yes

13

A18

Bidirectional

Yes

14

A16

Bidirectional

Yes

15

A19

Bidirectional

Yes

Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from

this table. The entire interface is represented in the eZ80L92 Module Schematics. see

eZ80L92 Module

.

2. The Power and Ground nets are connected directly to the eZ80L92 device.
Additional note: external capacitive loads on RD, WR, IORQ, MREQ, D0–D7 and A0–A23 should be
below 10 pF to satisfy the timing requirements for the eZ80

®

CPU. All unused inputs should be

pulled to either V

DD

or GND, depending on their inactive levels to reduce power consumption and

to reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80L92’s Peripheral Power-Down Register.