Zilog EZ80L92 User Manual
Page 16
eZ80L92 Development Kit
User Manual
Operational Description
UM012913-0407
12
Table 2. eZ80Acclaim!
®
Development Platform Peripheral Bus Connector
Identification—JP1
1
Pin No.
Symbol
Signal Direction
Active Level
eZ80L92 Signal
2
1
A6
Bidirectional
Yes
2
A0
Bidirectional
Yes
3
A10
Bidirectional
Yes
4
A3
Bidirectional
Yes
5
GND
6
V
DD
7
A8
Bidirectional
Yes
8
A7
Bidirectional
Yes
9
A13
Bidirectional
Yes
10
A9
Bidirectional
Yes
11
A15
Bidirectional
Yes
12
A14
Bidirectional
Yes
13
A18
Bidirectional
Yes
14
A16
Bidirectional
Yes
15
A19
Bidirectional
Yes
Notes:
1. For the sake of simplicity in describing the interface, Power and Ground nets are omitted from
this table. The entire interface is represented in the eZ80L92 Module Schematics. see
.
2. The Power and Ground nets are connected directly to the eZ80L92 device.
Additional note: external capacitive loads on RD, WR, IORQ, MREQ, D0–D7 and A0–A23 should be
below 10 pF to satisfy the timing requirements for the eZ80
®
CPU. All unused inputs should be
pulled to either V
DD
or GND, depending on their inactive levels to reduce power consumption and
to reduce noise sensitivity. To prevent EMI, the EZ80CLK output can be deactivated via software in
the eZ80L92’s Peripheral Power-Down Register.