beautypg.com

T*ap – Junger Audio T*AP Television Audio Processor Edition User Manual

Page 9

background image

T*AP

5

Base Unit rear view


For fail safe operation the Base Unit provides two independent power supplies. These power supplies
operate in load balance. The status of both PS are displayed on the Base Unit front panel as well as on the
X*AP Remote Panel.

STATUS LED

shows the status of the device controller

INIT

pressing the INIT button briefly will warm start the device controller.

Holding down the button until the STATUS LED flashes 3 times will initialize the
Base Unit to factory default

LAN

RJ45 socket for Ethernet connection to a LAN

USB

USB 2.0 type B socket to connect the built in USB >> serial converter with an
external PC

ISO-PWR LED

lights up if the isolated 5V power supply for GPI /O application is turned on

GPI

25pin Sub-D female connector to interface with the 8 optical isolated general
purpose inputs

GPO

25pin Sub-D female connector to interface with the 8 switch over relay general
purpose outputs

Interface 1

slot to mount one of the optional interface boards (SDI, AES, analog)

Interface 2

slot to mount one of the optional interface boards (SDI, AES, analog)

METADATA IN

9pin Sub-D female connector to receive and send Dolby® serial metadata

METADATA OUT

9pin Sub-D male connector to send Dolby® serial metadata

SYNC IN

75Ohm BNC connector to connect with external sync sources

WCKL-OUT

75Ohm BNC connector to synchronize external devices to the T*AP internal
word clock

AES IN 1/2 – 7/8

AES3id inputs

AES OUT 1/2 – 7/8

AES3id outputs