T*ap – Junger Audio T*AP Television Audio Processor Edition User Manual
Page 14
T*AP
10
getting started – IP setup of the Base Unit
–
via console interface
The tool to change the IP configuration of any Base Unit will be reached via the console interface. You must
connect the Base Unit with the PC via an USB A to B cable. This will install the driver for the built in USB to
serial converter. Now you can open a terminal program. Here you must select the virtual COM port
assigned by the OS. The communication parameters are :
115200kBaud, 8, N, 1 no hand shake. Pressing
Go for item 2 and press
"Your choice: 2"
"Current network configuration
IP Address :
10.110.24.128
Netmask ... :
255.255.0.0
Gateway ... :
10.110.0.1
You must enter the IP address and the netmask.
Enter new IP address, press ENTER to cancel : "192.168.176.78"
Enter new netmask, press ENTER to cancel : "255.255.255.0"
Important Note! The gateway entry is optional but you must take care that the gateway address matches the
network mask related to the device IP address!
If you re not sure simply enter 0.0.0.0.
Enter new gateway, press ENTER to configure without gateway : "0.0.0.0"
Network configuration has been changed. Please reboot the device
To activate the new settings.
Select item 8 and press
Do you want to reboot the device ?
Press small "y" :
Do you want to reboot the device ? y
Press
Rebooting the device ……..
After reboot has finished the new IP configuration is active.