T*ap – Junger Audio T*AP Television Audio Processor Edition User Manual
Page 43

T*AP
39
setup GUI – AUDIO PROCESSOR – Fail Over (4 x 2 program configuration)
For the 4x2 Program Configuration (SYSTEM > T*AP Program Configuration) the T*AP offers
four independent Fail Over circuits (see Overview sketch on page 34).
The source for the Fail Over circuit can be either the adjacent program input (e.g. input 2L/R for the
program input 1L/1R) or the AUX input. The Mode switch will select the respective signal path.
See the example above for the four program outputs :
program 1 (1L/1R)
has a valid input signal and is prepared for auto switch over
to the second program input 2L/2R.
program 2 (2L/2R)
has no valid input and has automatically switched over
to the AUX input.
program 3 (3L/3R)
has a valid input and is prepared for auto switch over
to input 4L/4R, input 4L/4R has valid input.
This is indicated by the yellow soft LED.