T*AP
58
technical data – Base Unit
• Power supply
dual power supply, auto fail over
AC 85 V – 264 V, 50 Hz … 60 Hz
58W max
• AES input
AES3id
24 Bit, 48 kHz, 0,32 … 1,2 Vpp
sample rate converters:
24 Bit, 32 kHz … 192 kHz, THD+N: < -130 dB @ 0 dBFS
• AES output
AES3id
24 Bit, 48 kHz, nominal 1 Vpp @ 75 Ohm
power fail relay bypass
• Sync internal
48 kHz, +/- 10 ppm
• Sync input
AES3id: 48 kHz, 0,32 … 1,2 Vpp @ 75 Ohm
Wordclock: 48 kHz, 1 … 3 V @ 75 Ohm
Video: Black Burst or Tri Level, 0.5 … 1.0V @ 75 Ohm
• Sync output
Wordclock 48 kHz: 2 V @ 75 Ohm
• Network
RJ45 rear connector
10/100MBit Ethernet auto sense, full duplex, auto MDI/X
RJ45 front panel connector
10/100MBit Ethernet auto sense, full duplex, auto MDI/X
Power Over Ethernet IEEE 802.3af
• USB
USB 2.0 connector to internal console interface
• GPI
3 V – 30 V balanced, auto polarity
• GPO
relay change over contacts, 200mA/24V (DC/AC)
• Environmental
operating temperature 0 ºC to 50 ºC
Base Unit - fan cooled
non operating -20 ºC to 70 ºC
humidity 90%, non condensing
• Dimensions
19", 1RU, depth 27 cm
and Weight
net weight approx. 5 kg shipping weight 7,5 kg
technical data – X*AP Remote Panel
• Power supply
POE (Power Over Ethernet), IEEE 802.3af
• Consumption
8 W
• Max cable length
if connected with the Base Unit, 30m distance CAT.5E (26AWGx4P)
• Dimensions
19", 1RU, depth 6 cm
• Environmental
operating temperature 0 ºC to 50 ºC
non operating temperature -20 ºC to 70 ºC
humidity 90%, non condensing