T*AP
19
This T*AP
input fields for information utilized by higher level services.
Name
give the device a meaningful name that may be used by name services
and SNMP management.
Location
the place where the T*AP is located.
Admin / Contact
e-mail address of a person in charge.
Graphical User Interface
defines the appearance of the parameter panes regarding preset editor
and on air parameter visibility (see below – for preset concept).
Device Time
allows you to set the device clock. At the factory it is set to
UTC (Coordinated Universal Time).
Date
if you click into the Date input field,
a comfortable calendar tool will pop up :
Time
if you click into the Time
input field, you will be able to
set the device time
Network
IP address setup, see above:
getting started – IP setup of the Base Unit
–
via web browser
IP Address
Netmask
Gateway
Transmit Metering Data
metering data will be streamed via UDP protocol. In order to receive such
data by external applications you must define ports (port range) for
matching fire wall definitions.
Enable
enables UDP port range use by the device for transferring meter data
from the Base Unit to the PC where the browser resides.
UDP Port Range Start lowest port number.
UDP Port Range End
highest port number.
Service Options
Maintenance Interface
via RPC
for in house use to enable communication with factory tools.
Telnet Server
enables a telnet server to connect the consol interface via IP (port 21).
Diagnostics
get diagnostics file
pressing this soft button will start the assembly of a diagnostics file.
The file will be presented in XML format for download.
If you experience unexpected behavior of the device you may be asked by
the Junger service team to send such file by e-mail for analysis.