beautypg.com

T*ap – Junger Audio T*AP Television Audio Processor Edition User Manual

Page 27

background image

T*AP

23

set up GUI – INTERFACES – AES I/O

Input Status

each AES input has a status detection that may show :
PCM, Non PCM (e.g. Dolby encoded signal) or
Fail (no carrier, unlock, cranky [too much jitter]).
The non PCM status will be retrieved from a logical combination of
the Validity flag and the channel status.

If one of the inputs is not assigned by the ROUTING section, its
status will not be incorporated into the System Status.

Input Sample Rate Converter

for asynchronous sources it is possible to turn a SRC on per input.
If a SRC is turned on and the input status becomes Non-PCM, the
respective SCR will be turned off automatically in order to maintain
the original data structure of an encoded bit stream like Dolby E.

AES Relay Bypass

the power fail bypass relays of all 4 I/Os may be activated manually.

It is possible to exclude AES I/Os from the relay bypass circuit.

You must open the cover plate from the Base Unit and locate
the 4 jumpers shown in the schematic below.

They are located close to the 9-pin Dolby
metadata OUT connector at the rear.

You must remove the jumper to exclude the respective AES I/O.

Output Channel Status

the channel status can be either
transparent from the input source
of the T*AP or may be overwritten.
The pull down offers these options :