CANopen User Manual
0x1800~0x1803 TPDO communication parameter
Contains the communication parameters for the PDOs the device is able to transmit.
The type of the PDO communication parameter (20h) is described in 9.5.4 of CiA 301. A
detailed description of the entries is done in the section for the Receive PDO Communication
Parameter (1400h – 1403h).
Object Type
Sub Number
Record
7
Subindex
Name
Data Type
Access
Type
PDO
Mapping
COS
Default value
00
max sub-index
UNSIGNED8
ro
no
no
6
01
COB-ID used by TPDO UNSIGNED32
rw
no
no
0x180+$NODEID3
02
transmission type
UNSIGNED8
rw
no
no
255
03
inhibit time
UNSIGNED16
rw
no
no
100
04
compatibility entry
UNSIGNED8
rw
no
no
0
05
event timer
UNSIGNED16
rw
no
no
0
06
SYNC start value
UNSIGNED8
rw
no
no
0
0x1800 - 0x1803 TPDO communication parameter
max sub-index
COB-ID
bit 0-10: COB-ID for PDO, to change it bit 31 must be set
bit 11-29: set to 0 for 11 bit COB-ID
bit 30: 0(1) - RTR are allowed (are NOT allowed) for PDO
bit 31: 0(1) - node uses (does NOT use) PDO
Transmission type
value = 0: transmiting is synchronous, specification in device profile
value = 1-240: transmiting is synchronous after every N-th SYNC object
value = 241-251: not used
value = 252-253: Transmited only on reception of Remote Transmission Request
value = 254: manufacturer specific
value = 255: asinchronous, specification in device profile
inhibit time
bit 0-15: Minimum time between transmissions of the PDO in 100µs. Zero disables
functionality.
compatibility entry
bit 0-7: Not used.