CANopen User Manual
Object Type
Sub Number
Record
5
Subindex
Name
Data Type
Access Type
PDO
Mapping
COS
Default value
00
max sub-index
UNSIGNED8
ro
no
no
4
01
Vendor-ID
UNSIGNED32
ro
no
no
0x000002D9
02
Product code
UNSIGNED32
ro
no
no
0x00000000
03
Revision number
UNSIGNED32
ro
no
no
0x00000000
04
Serial number
UNSIGNED32
ro
no
no
0x00000000
max sub-index
Vendor-ID
bit 0-31: Assigned by CiA (here is 0x000002D9 for Shanghai AMP and Applied Motion
Products Automation)
Product code
bit 0-31: Manufacturer specific
Revision number
bit 0-15: Minor revision num. (CANopen behavior has not changed)
bit 16-31: Major revision number (CANopen behavior has changed)
Serial number
bit 0-31: Manufacturer specific (Lot Number)
0x1019 Synchronous counter overflow value
This object contains the max counters of SYNC message. If it is 0 the producer will send
the SYNC message without any data, otherwise with data length 1.
Object Type
Data Type
Access Type
PDO Mapping
COS
Default value
Var
UNSIGNED8
rw
no
no
0
If value is zero, then SYNC message is transmitted with data length 0.
If value is from 2 to 240, then SYNC message has one data byte, which contains the
counter.
Other values are reserved.