][BA_Betrieb Störung LED "Err" Sys A + B

A module error is displayed via the "Err" LED (see section entitled "Dis-

play elements"), signalled to the head module and then entered in the

head module's

Error stack, with PSSu in system environment A

Diagnostic log, with PSSu in system environment B.

][BA_Betrieb Fehler ST-Zhler

The module can detect the following errors:

Module error

Explanation

Remedy

Start-up error

Error as the PSSu system starts up

Change faulty module.

Configuration error

Incorrect module type configured.

The configured hardware registry does
not match the actual hardware regis-
try.

ST communication error

Error during ST communication Change

faulty

module.

Bus termination error

There is no terminating plate or there is
a bad contact with the module bus.

Install a terminating plate with inte-
grated end bracket or insert the base
modules together correctly.