6.3

Connecting the module

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-6

Counter operating mode

With C-rail

Encoder supply via the
PSSu E PD module
Functional inputs (G, L, S) not
connected.

Counter operating mode

Without C-rail

Encoder supply via the
PSSu E PD module
Functional inputs (G, L, S) not
connected.

21

11

22

12

23

13

24

14

41

31

42

32

43

33

44

34

C+ (Gate)

B+ (Up/Down)

C-
B-
A-

A+ (Count)

0 V

21

11

22

12

23

13

24

14

41

31

42

32

43

33

44

34

C+ (Gate)

B+ (Up/Down)

C-
B-
A-

A+ (Count)

0 V