Pilz PSSu E F 2DOR 8 User Manual
Page 29

Technical details
Operating Manual PSSu E F 2DOR 8(T)(R)
21334EN07
29
Relay outputs
312225
314225
315225
Contact fuse protection,
external safety contacts
In accordance with the
standard
VDE 0660
VDE 0660
VDE 0660
Blowout fuse, quick
10 A
10 A
10 A
Blowout fuse, slow
6 A
6 A
6 A
Max. processing time of
relay output when signal
changes from "1" to "0"
120 ms
120 ms
120 ms
Max. processing time of
relay output when signal
changes from "0" to "1"
60 ms
60 ms
60 ms
Contact material
AgCuNi + 0,2 µm Au
AgCuNi + 0,2 µm Au
AgCuNi + 0,2 µm Au
Potential isolation
between relay contact and
periphery supply
4900 V (prot. separation) 4900 V (prot. separation) 4900 V (prot. separation)
Potential isolation
between relay contact and
module supply
4900 V (prot. separation) 4900 V (prot. separation) 4900 V (prot. separation)
Potential isolation
between relay contact and
Crail
3050 V (basic insulation) 3050 V (basic insulation) 3050 V (basic insulation)
Potential isolation
between relay contact 1
and relay contact 2
4900 V (prot. separation) 4900 V (prot. separation) 4900 V (prot. separation)
Environmental data
312225
314225
315225
Application site
In accordance with the
standard
–
–
EN 501253
Application site
–
–
Track area (1 m 3 m)
In accordance with the
standard
–
–
EN 61373
Application site
–
–
Category 1, Class A + B
Climatic suitability
EN 6006821, EN
60068214, EN
6006822, EN
60068230, EN
60068278
EN 6006821, EN
60068214, EN
6006822, EN
60068230, EN
60068278
EN 501251, EN 501253,
EN 50155, EN 6006821,
EN 60068214, EN
6006822
Ambient temperature
In accordance with the
standard
EN 60068214
EN 60068214
EN 50155
Temperature range
0 60 °C
40 60 °C
40 70 °C
Max. temperature in
accordance with UL
60 °C
60 °C
–
In accordance with the
standard
–
–
EN 501251
Temperature range
–
–
40 ... +70 °C
In accordance with the
standard
–
–
EN 501253
Temperature range
–
–
40 ... +70 °C