beautypg.com

Operation, Messages, 1 display elements – Pilz PNOZ ms2p TTL coated version User Manual

Page 35: 1 display elements for device diagnostics, 7operation, 1 messages

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-1

7.1

Messages

7

Operation

7

7000

Operation

Operation

7-

7.1

Messages

7100

Messages

7-

Betrieb_Meldungen_allgemein_BA

When the supply voltage is switched on, the PNOZmulti safety system

copies the configuration from the chip card.

The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up

on the base unit.

Betrieb_Meldungen_Modul_Ready_BA

The PNOZmulti safety system is ready for operation when the "POWER"

and "RUN" LEDs on the base unit and the "READY" LED on the PNOZ

ms2p TTL are lit continuously.

7.1.1

Display elements

Display elements

7-

Anzeige Legende 3x

Key:

7.1.1.1

Display elements for device diagnostics

Display elements for device diagnostics

7-

Betrieb_Anzeige_multi_Drehzahlwaechter_BA

LED on

LED flashes

LED off

LED

LED status

Meaning

POWER

Supply voltage is present

FAULT

External fault leading to a safe condition; the fault is at the incremental encoder in-
puts whose LEDs are flashing, e.g. short across the contacts

Internal fault leading to safe condition

SHAFT1
SHAFT2

Encoder or wiring fault

Axis 1 and/or axis 2 are in the normal range (no standstill, no overspeed)

Axis 1 and/or axis 2 signalling standstill

Axis 1 and/or axis 2 signalling overdrive

X12
X22

Incremental encoders on terminals X12 and/or X22 are connected correctly

I10, I11, I20,
I21

Proximity switch on terminal I10, I11, I20, I21 is energised

This manual is related to the following products: