beautypg.com

2 adapter for incremental encoders, 4function description, 2 input device types – Pilz PNOZ ms2p TTL coated version User Manual

Page 19

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-3

4.2

Input device types

4

Function description

4.2.2.2

Adapter for incremental encoders

Adapter for incremental encoders

4-

Drehzahlwaechter_Inkrementalgeber_Adapter

The adapter records the data between the incremental encoder and the

drive and makes it available to the speed monitor via the RJ-45 female

connector.

Pilz supplies complete adapters as well as ready-made cable with RJ-

45 female connectors, which can be used when making an individual

adapter. The range of products in this area is constantly being expand-

ed. Please contact us about the range of adapters that is currently avail-

able.

4.2.3

Incremental encoder and proximity switch on one axis

Incremental encoder and proximity switch on one axis

4-

Drehzahlwaechterr_Naeherungssch_Inkrement_auf_einer_Achse

In order to increase the availability, a proximity switch and an incremen-

tal encoder can be configured on one axis for the speed monitor. That

way the speed monitor can monitor 3 signals on one axis: Track A and

track B of the incremental encoder and the proximity switch:

Standstill monitoring

Standstill is detected when at least two of these signals fall below the

standstill frequency.

Monitoring for broken shearpins

If the Broken shearpin monitoring option is activated, a shearpin break

is recognised if

`

both signals of the incremental encoder fall below the set standstill

frequency (standstill)

and

`

the proximity switch exceeds the set standstill frequency (rotating

shaft).

The recognised broken shearpin leads to safe condition (see status B2

in "Signal statuses" table in Chapter 8 of the operating manual). If indi-

vidual or multiple signals change, the safe condition is cleared again as

required (see "Signal statuses" table).

Hazards that can arise through an automatic restart must be excluded

within the user program.

This manual is related to the following products: