Operation, Messages, Display elements – Pilz PNOZ ms4p speedcontrol User Manual
Page 25: 1 display elements for unit diagnostics, 7operation, 1 messages
![background image](https://www.manualsdir.com/files/762662/content/doc025.png)
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-1
7.1
Messages
7
Operation
7
7000
Operation
Operation
7-
7.1
Messages
7100
Messages
7-
When the supply voltage is switched on, the PNOZmulti safety system
copies the configuration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up
on the base unit.
The PNOZmulti safety system is ready for operation when the "POWER"
and "RUN" LEDs on the base unit and the "READY" LED on the PNOZ
ms4p are lit continuously.
7.2
Display elements
7200
Display elements
7-
Key:
7.2.1
Display elements for unit diagnostics
Display elements for unit diagnostics
7-
LED on
LED flashes
LED off
LED
LED status
Key
POWER
Supply voltage is present
FAULT
External fault leading to a safe condition; the fault is at the incremental encoder in-
puts whose LEDs are flashing, e.g. short across the contacts
Internal fault leading to safe condition
SHAFT
Input device or wiring fault
Axis is in the normal range (no standstill, no overspeed)
Axis is signalling standstill
Axis is signalling overspeed
X12
Incremental encoder on terminal X12 is connected correctly