7.1

Messages

7

Operation

7

7000

Operation

Operation

7-

7.1

Messages

7100

Messages

7-

When the supply voltage is switched on, the PNOZmulti safety system

copies the configuration from the chip card.

The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up

on the base unit.

The PNOZmulti safety system is ready for operation when the "POWER"

and "RUN" LEDs on the base unit and the "READY" LED on the PNOZ

ms4p are lit continuously.

7.2

Display elements

7200

Display elements

7-

Key:

7.2.1

Display elements for unit diagnostics

Display elements for unit diagnostics

7-

LED on

LED flashes

LED off

LED

LED status

Key

POWER

Supply voltage is present

FAULT

External fault leading to a safe condition; the fault is at the incremental encoder in-
puts whose LEDs are flashing, e.g. short across the contacts

Internal fault leading to safe condition

SHAFT

Input device or wiring fault

Axis is in the normal range (no standstill, no overspeed)

Axis is signalling standstill

Axis is signalling overspeed

X12