background image

Overview

Operating Manual PNOZ mm0p-T
1002704-EN-01

7

Overview

Unit structure

Range

}

Base unit

PNOZ mm0p-T

}

Documentation on data medium

Unit features

Using the product

PNOZ mm0p-T:

Base unit from the configurable control system PNOZmulti
The product has the following features:

}

Can be configured in the PNOZmulti Configurator

}

Semiconductor outputs:

4 safety outputs

Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3 of EN
IEC 62061

}

12 inputs for connecting, for example:

– E-STOP pushbuttons
– Two-hand pushbuttons
– Safety gate limit switches
– Reset buttons
– Light beam devices
– Scanners
– Enabling switches
– PSEN
– Operating mode selector switches
– Pressure sensitive mats

}

8 configurable inputs/outputs

Can be configured as:

– Inputs (see above for connection options)

or

– Outputs for standard applications

}

4 configurable outputs

Can be configured as:

– Outputs for standard applications

or

– Test pulse outputs

}

LED for:

2

2.1

2.1.1

2.1.2