beautypg.com

Safety characteristic data – Pilz PZE X4V 0,5/24VDC 4n/o fix User Manual

Page 15

background image

PZE X4V

Operating Manual PZE X4V
1003200­EN­08

15

Mechanical data

774586

774583

Mounting position

Any

Any

Mechanical life

10,000,000 cycles

10,000,000 cycles

Material

Bottom

PPO UL 94 V0

PPO UL 94 V0

Front

ABS UL 94 V0

ABS UL 94 V0

Top

PPO UL 94 V0

PPO UL 94 V0

Conductor cross section with screw
terminals

1 core flexible

0,20 ­ 4,00 mm², 24 ­ 10 AWG

0,20 ­ 4,00 mm², 24 ­ 10 AWG

2 core with the same cross sec­
tion, flexible with crimp connect­
ors, no plastic sleeve

0,20 ­ 2,50 mm², 24 ­ 14 AWG

0,20 ­ 2,50 mm², 24 ­ 14 AWG

2 core with the same cross sec­
tion, flexible without crimp con­
nectors or with TWIN crimp con­
nectors

0,20 ­ 2,50 mm², 24 ­ 14 AWG

0,20 ­ 2,50 mm², 24 ­ 14 AWG

Torque setting with screw terminals 0,50 Nm

0,50 Nm

Connection type

Screw terminal

Screw terminal

Mounting type

Fixed

Fixed

Dimensions

Height

87,0 mm

87,0 mm

Width

22,5 mm

22,5 mm

Depth

121,0 mm

121,0 mm

Weight

185 g

210 g

The standards current on 2009­12 apply.

Safety characteristic data

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

Safety con­
tacts,
delayed <30
s

PL d

Cat. 3

SIL CL 2

2,48E­09

SIL 2

1,47E­05

20

All the units used within a safety function must be considered when calculating the safety
characteristic data.

INFORMATION

A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.