Safety characteristic data – Pilz PZE X4V 0,5/24VDC 4n/o fix User Manual
Page 15

PZE X4V
Operating Manual PZE X4V
1003200EN08
15
Mechanical data
774586
774583
Mounting position
Any
Any
Mechanical life
10,000,000 cycles
10,000,000 cycles
Material
Bottom
PPO UL 94 V0
PPO UL 94 V0
Front
ABS UL 94 V0
ABS UL 94 V0
Top
PPO UL 94 V0
PPO UL 94 V0
Conductor cross section with screw
terminals
1 core flexible
0,20 4,00 mm², 24 10 AWG
0,20 4,00 mm², 24 10 AWG
2 core with the same cross sec
tion, flexible with crimp connect
ors, no plastic sleeve
0,20 2,50 mm², 24 14 AWG
0,20 2,50 mm², 24 14 AWG
2 core with the same cross sec
tion, flexible without crimp con
nectors or with TWIN crimp con
nectors
0,20 2,50 mm², 24 14 AWG
0,20 2,50 mm², 24 14 AWG
Torque setting with screw terminals 0,50 Nm
0,50 Nm
Connection type
Screw terminal
Screw terminal
Mounting type
Fixed
Fixed
Dimensions
Height
87,0 mm
87,0 mm
Width
22,5 mm
22,5 mm
Depth
121,0 mm
121,0 mm
Weight
185 g
210 g
The standards current on 200912 apply.
Safety characteristic data
Operating
mode
EN ISO
138491:
2008
PL
EN ISO
138491:
2008
Category
EN IEC
62061
SIL CL
EN IEC
62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
138491:
2008
T
M
[year]
Safety con
tacts,
delayed <30
s
PL d
Cat. 3
SIL CL 2
2,48E09
SIL 2
1,47E05
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use