beautypg.com

Pilz PZE X4V 0,5/24VDC 4n/o fix User Manual

Page 10

background image

PZE X4V

Operating Manual PZE X4V
1003200­EN­08

10

Relay outputs

774580

774581

774582

Utilisation category

In accordance with the
standard

EN 60947­4­1

EN 60947­4­1

EN 60947­4­1

Safety­contacts,
delayed, AC1 at

240 V

240 V

240 V

Min. current

0,01 A

0,01 A

0,01 A

Max. current

6,0 A

6,0 A

6,0 A

Max. power

1500 VA

1500 VA

1500 VA

Safety­contacts,
delayed, DC1 at

24 V

24 V

24 V

Min. current

0,01 A

0,01 A

0,01 A

Max. current

6,0 A

6,0 A

6,0 A

Max. power

150 W

150 W

150 W

Utilisation category

In accordance with the
standard

EN 60947­5­1

EN 60947­5­1

EN 60947­5­1

Safety contacts,
delayed AC15 at

230 V

230 V

230 V

Max. current

3,0 A

3,0 A

3,0 A

Safety contacts
delayed DC13 (6
cycles/min) at

24 V

24 V

24 V

Max. current

4,0 A

4,0 A

4,0 A

Utilisation category in ac­
cordance with UL

Voltage

250 V AC G.U. (same po­
larity)

250 V AC G.U. (same po­
larity)

250 V AC G.U. (same po­
larity)

With current

6,0 A

6,0 A

6,0 A

Voltage

24 V DC G. U.

24 V DC G. U.

24 V DC G. U.

With current

6,0 A

6,0 A

6,0 A

Pilot Duty

B300, R300

B300, R300

B300, R300

Contact fuse protection
external, safety contacts

In accordance with the
standard

EN 60947­5­1

EN 60947­5­1

EN 60947­5­1

Contact fuse protection
external, delayed safety
contacts

Max. melting integral

66 A²s

66 A²s

66 A²s

Blow­out fuse, quick

6 A

6 A

6 A

Blow­out fuse, slow

4 A

4 A

4 A

Blow­out fuse gG

6 A

6 A

6 A

Circuit breaker, 24
V AC/DC, character­
istic B/C

4 A

4 A

4 A

Contact material

AgCuNi + 0,2 µm Au

AgCuNi + 0,2 µm Au