background image

DXIFS-160/RAID User's Guide - Rev. B00

StorCase Technology, Inc.

Appendix C - Troubleshooting

65

Disk Detected Errors

Figure C-2 shows a typical disk detected error. Refer to Table C-4 for Sense Key codes and

their descriptions.

Figure C-2: Typical Disk Detected Error

DISK DETECTD ERR

2 : 0 5 0 3 , 11 , 0 b

IFS_62

Disk Channel

SCSI ID
Sense Key
Sense Code
Sense Code Qualifier

Sense KeyDescription

IFS_64

0h
1h
2h
3h
4h

No sense
Recovered error
Not ready
Medium error
Hardware error

5h
6h
7h
8h
9h
Ah
Bh
Ch
Dh

Eh

Fh

Illegal request
Unit attention
Data protect
Blank check
Vendor-specific
Copy aborted
Aborted command
Obsolete
Volume overflow
Miscompare
Reserved

Table C-4: Sense Key Codes and Descriptions