DXIFS-160/RAID User's Guide - Rev. B00

StorCase Technology, Inc.

Configuration

37

Utility Priority

This command allows the user to change the priority at which all utilities run, when there are

active I/O operations competing for the controller's CPU. The choices are:

High
Medium

Low

For example, select High if the highest priority is to get the array back to a fully fault-tolerant

state. This will cause heavy I/O with the host to be slower than normal. Select Low if streaming

data without interruption is more important than data redundancy. This allows the Reconstruct

utility to compete at a slower rate with minimal effects on host I/O.

Alarm Mute

This command allows the user to mute (or unmute) the controller's onboard alarm. The setting

selected remains in effect until it is changed again by using this option.

New Sample Rate

NOTE:

Default sample rate is 1 second.

This command allows the user to set the frequency at which the controller samples data when

updating status screens. To change the sample rate, use é or ê keys.

Restore Defaults

This command allows the user to restore all of the configuration options back to their factory

default settings.