Array menu, Array status – StorCase Technology SCSI-to-SCSI Single RAID User Manual
Page 26

16
Configuration
StorCase Technology, Inc.
DXIFS-160/RAID User's Guide - Rev. B00
Array Menu
The Array Menu can only be selected if there are one or more active arrays. A summary list
of arrays is displayed. Each line in the list displays the array's number, LUN, RAID level, state,
utility running, size, and name (thus, providing a quick overview of the entire RAID configuration
without going to lower level menus). After choosing one of the arrays, select one of the options
listed below:
Array Status
Drive Status
Array Statistics
Abort Initialization
Verify Function
Expand Function
Add Spare
Delete Spare
Change LUN
Change Array Name
Trust Array
Array Status
The Array Status (Figure 10) displays the following information:
State - Online, Offline, Critical, or Fault-tolerant.
Serial number of the array - Each array is assigned a unique serial number.
Name - The name given to the array.
RAID - RAID type (0, 3, 4, 5, 50, Volume, or Mirrored). The term mirrored is used
for RAID 1, RAID 0/1, and RAID 10 arrays.
Number of drives in the array when fault-tolerant (For example, if a three drive
RAID 5 array was created and one drive is lost, the number will still show three
drives).
Number of spare drives dedicated to this array.
TID and LUN number - Target ID and LUN number presented to the host system.