background image

DXIFS-160/RAID User's Guide - Rev. B00

StorCase Technology, Inc.

Appendix C - Troubleshooting

67

Disk Channel Errors

NOTE:

Most disk channel errors are informational, since the controller will retry to correct

any problem.

Disk channel errors occur while talking to back-end devices that are detected by the controller

rather than the disk drive. An example is a parity error on data received from a disk drive.

Some disk channel errors are displayed as text strings, others are displayed as hexadecimal

codes. Figure C-3 shows a typical disk channel error and accompanying hexadecimal code.

Refer to Table C-5 for Error Codes and their descriptions.

DISK CHANNEL ERR

1 : 0 0 Ts k Sta t : 3 1

IFS_63

Disk

Channel

SCSI ID

Error

Code

Figure C-3: Typical Disk Channel Error

Voltage and Temperature Errors and Warnings

Most voltage and temperature errors occur due to the enclosure. Check the InfoStation first

when experiencing these types of problems.