Disk channel errors, Voltage and temperature errors and warnings – StorCase Technology SCSI-to-SCSI Single RAID User Manual
Page 77

DXIFS-160/RAID User's Guide - Rev. B00
StorCase Technology, Inc.
Appendix C - Troubleshooting
67
Disk Channel Errors
NOTE:
Most disk channel errors are informational, since the controller will retry to correct
any problem.
Disk channel errors occur while talking to back-end devices that are detected by the controller
rather than the disk drive. An example is a parity error on data received from a disk drive.
Some disk channel errors are displayed as text strings, others are displayed as hexadecimal
codes. Figure C-3 shows a typical disk channel error and accompanying hexadecimal code.
Refer to Table C-5 for Error Codes and their descriptions.
DISK CHANNEL ERR
1 : 0 0 Ts k Sta t : 3 1
IFS_63
Disk
Channel
SCSI ID
Error
Code
Figure C-3: Typical Disk Channel Error
Voltage and Temperature Errors and Warnings
Most voltage and temperature errors occur due to the enclosure. Check the InfoStation first
when experiencing these types of problems.