beautypg.com

Weighing problems, Weighing problems -11 – Pitney Bowes DM550 Series User Manual

Page 167

background image

DM500™ and DM550™Series Digital Mailing System Operating Guide

SV61436 Rev. D

10-11

Weighing Problems

Description

Possible Causes

Solution

Weight on internal

scale is erratic

Possible interference.

Remove everything from the scale and turn off

the power. Rezero the scale. To rezero the

scale, press the Menu key, then select Zero
Scale

.

Make sure when you place mail on the scale

you center it and check to make sure that it is

not touching another surface.

Weights on external

scale are erratic or

the scale does not

return to zero

For MP Series External Weighing

Platform scales: The scale top

cover my not be seated properly

on the scale

1. Remove the top cover and make sure the 4

plastic grommets in the scale are seated

properly. The 4 plastic posts on the top

cover fit into these grommets.

2. If a grommet, or any part of a grommet, is

pushed below the surface of the metal on

the scale, reseat it until it appears as shown

here:

3. Check to make sure the bubble is centered

in the circle as shown on the next page. If

not, and you have a flatblade screwdriver,

center the bubble by adjusting the legs,

otherwise go to step 4.

Grommet seated
properly

Grommet pushed
below surface

Center the bubble

This manual is related to the following products: