9 • Maintaining and Updating

9 - 8

SV61436 Rev. D

5. Remove the wick, using

the metal shield to gently

pry it out of the moistener

tank.

6. Drain the moistener tank

over the front of the

machine into a receptacle

as shown here.

7. To clean the moistener tank, remove the E-Z Seal® Sealing Solution

supply tube and wipe out the tank with E-Z Seal® solution.

Clean the wick by holding it under running water.

8. Push the supply tube back onto the moistener tank nozzle. Push the

tube back on as far as it will go to prevent leaking.