Yb,p,d,s - rs232 serial port communication setting, Z - reset to factory default settings, Yb,p,d,s – GoDEX EZPL User Manual
Page 26
![background image](/manuals/736893/26/background.png)
21
^Yb,p,d,s - RS232 serial Port communication setting
Syntax
^Yb,p,d,s
Parameter
b = Baud Rate
48=4800bps
96=9600bps
19=19200bps
38=38400bps
57=57600bps
11=115200bps
p = Parity (N, O, E)
N=none parity
O=odd parity
E=even parity
d = Number of data bits 7
8
s = Number of stop bits
1
2
Description
Serial Port communication setting
^Z - Reset to factory default settings
Syntax
^Z
Parameter
^Z: default value comes from EEPROM default area.
Description
Reset to factory default. Same as ~~INTERNALCOMMAND+INIT