beautypg.com

15 replacement of parts – Glow-worm Ultrapower sxi Range User Manual

Page 67

background image

67

RETAINING

CLIPS

CONTROL

BOX

15.33 Access to Control Box Internals

For access, refer to section 15.1.
Carefully pull the control box forwards so that it lies

horizontally in its hinges.
Do not allow the front of the control box to swing down and be

loosely held by its electrical connections.
Release the four retaining clips, see diagram 15.27, to

remove the rear cover and gain access to the electrical

connections, main PCB and appliance interface PCB.

15.34 Main PCB

For access, refer to section 15.33.
Remove the electrical connections to the PCB.
Ease back the four PCB retaining clips and withdraw the PCB

from the retaining lugs, see diagram 15.28.
When refitting the control box cover ensure the leads do not

become trapped.

15.35 Fuse, Main PCB - Control Box

For access, refer to section 15.33.
The fuse is located at top left hand side of the main PCB, see

diagram 15.28.

15.36 User Interface

Refer to section 15.33 for access.
Remove the main PCB, refer to section 15.34.
Remove the electrical connection.
Gently ease back the retaining clips, see diagram 15.29.
Withdraw the board.
When replacing the board refer to instructions supplied with

replacement PCB.

15.37 Boiler Module Front Casing Panel Seal

Remove the seal and thoroughly clean the casing surface

before fitting the new seal, see diagram 13.15.
Refit the casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

15 Replacement of Parts

Diagram 15.29

MAIN PCB

RETAINING

CLIP (4 OFF)

ELECTRICAL

CONNECTION

RETAINING

LUG (2 OFF)

FUSE

Diagram 15.28

13372

Diagram 15.27

13446

APPLIANCE

INTERFACE

PCB

RETAINING

CLIPS

ELECTRICAL

CONNECTION

13355